Commit graph

1433 commits

Author SHA1 Message Date
Benjamin Berg
685052c605 tests: Add test for vfs0050 driver
This test is based on data captured by Evgeny.

Co-authored-by: Evgeny Gagauz <evgenij.gagauz@gmail.com>
2020-06-05 15:03:38 +00:00
Benjamin Berg
4b83f8bfd9 vfs0050: Accept zero bytes read instead of timeout for emulation
This allows us to replace non-emulateable timeout conditions into zero
byte replies in the recording.
2020-06-05 15:03:38 +00:00
Benjamin Berg
b137807420 upekts: Fix error reporting during verify
We delayed the wrong error types for the early reporting mechanism.
2020-06-05 14:48:57 +00:00
Benjamin Berg
0936fc3597 upekts: Fix error handling in verify_stop_deinit_cb
The error memory management was incorrect possibly causing double free's
and critical warnings.
2020-06-05 14:48:57 +00:00
Benjamin Berg
b7f436e8de upekts: Fix reading of fingerprint data for verification
the code tried to fetch the data from the device rather the print.
Obviously, this could never work.
2020-06-05 14:48:57 +00:00
Benjamin Berg
4f0b0fa526 tests: Ensure FpDevice checks enrolled prints for completeness
Enrolled prints need to have their type set. FpDevice should ensure that
is the case when a driver returns a print back.
2020-06-05 14:48:57 +00:00
Benjamin Berg
f0abefa9fa device: Ensure enrolled print as an appropriate type set
The driver might forget to set the type of the print. Catch that error a
bit earlier rather than failing when the API user tries to load it from
disk again.
2020-06-05 14:48:57 +00:00
Benjamin Berg
7f58556011 tests: An enrolled print needs to have a type set 2020-06-05 14:48:57 +00:00
Benjamin Berg
cecb01bcb9 upekts: Set the print type during enroll
The type of the print (RAW or NBIS) needs to be filled in by the driver.
For most drivers the image devices does this (NBIS), but the
corresponding call was missing in the upekts driver, rendering the
enrolled print unusable.
2020-06-05 14:48:57 +00:00
Benjamin Berg
b95402bc72 upekts: Fix memory leak and remove unneeded copy
__handle_incoming_msg would copy the payload of the message into a newly
created buffer just to destroy it again immediately after calling the
callback. Just reference the correct address inside the original package
instead.

Also, in one case the extra buffer was leaked afterwards.
2020-06-05 14:48:57 +00:00
Benjamin Berg
484743f652 upekts: Assert correct packet length in __handle_incoming_msg
The surrounding code already checks this and reads the correct amount.
Add an assert to ensure we really never do an out of bounds read.
2020-06-05 14:48:57 +00:00
Benjamin Berg
a5cfc1644f upekts: Fix 9 byte buffer overflow while reading extended data
The driver would correctly calculate the amount of extra space needed to
receive the whole packet. It would also request the correct number of
bytes for this transfer.

However, the reallocated buffer to hold this data was directly derived
from the expected payload size and did not include the overhead.

Make the code more explicit and get rid of the confusing
MAX_DATA_IN_READ_BUF define that hides details on buffer allocation
calculation from the code.
2020-06-05 14:48:57 +00:00
Benjamin Berg
b3565b83e1 upekts: Only release USB interface on exit
The device is already beeing de-initialised from the verify/enroll
commands. Trying it again will result in a timeout error as it is not
responding properly at that point.
2020-06-05 14:48:57 +00:00
Benjamin Berg
8f46de0a60 upekts: Fix reference counting in do_enroll_stop
The print passed to do_enroll_stop does not need to be ref'ed in the
function.
2020-06-05 14:48:57 +00:00
Benjamin Berg
b3c5fe4b82 upekts: Fix ownership transfer to fpi_device_enroll_complete
fpi_device_enroll_complete takes the ownership of the pointers. As such,
they need to be stolen from EnrollStopData.
2020-06-05 14:48:57 +00:00
Vasily Khoruzhick
4cf5f92a52 lib: re-add partial image flag
And activate perimeter points removal if this flag is set

This flag should be set for aes1610, aesx660, aes2501, aes2550
and upektc_img since these sensors may produce incomplete image.

Fixes: #142
2020-06-04 09:34:31 -07:00
Vasily Khoruzhick
297236b51a nbis: re-add step to remove perimeter points
This step helps to drop false minutiae for short sensors and
it was accidentally dropped during NBIS update. Re-add this step
and add a patch to update script to ensure that it's not dropped
during next update.

Fixes: 9fb789dc78 ("nbis: Update to NBIS 5.0.0")
2020-06-03 20:44:41 -07:00
Benjamin Berg
8626c64831 ci: Output diff of uncrustify check
Not having the diff is a bit painfull when the local version of
uncrustify differs from the one on the CI runner. So uncrustify in-place
and output the diff.
2020-06-02 11:56:19 +00:00
Benjamin Berg
e4f9935706 Uncrustify with newer version 2020-06-02 11:56:19 +00:00
Benjamin Berg
8ba29606bb Add MAINTAINERS file 2020-05-22 15:00:11 +02:00
Evgeny Gagauz
1b74813adf vfs0050: Stop capture after a timeout happens
If a transfer errors out then actual_length is negative. The only error
that is not caught is a timeout error, which should also result in the
SSM to move to the next state.
2020-05-13 09:51:23 +00:00
Benjamin Berg
07ff03970f libfprint: Fix a few issues with the documentation
This must have been broken all along. Get it into a better shape. Looks
like mostly cases of bad copy/paste.
2020-05-11 20:51:29 +02:00
Benjamin Berg
25ab4849a4 doc: Move sections and fix title for internal FpImageDevice
Otherwise the public API page (which is empty) is overwritten.
2020-05-11 20:51:29 +02:00
Benjamin Berg
840bcc77a5 ci: Export HTML documentation as artifacts
We build the HTML documentation. For feature branches, it is convenient
to be able to view the documentation easily. Expose them as artifacts
and add a link to the browser underneath the pipeline in the MR.

Unfortunately, it does not seem to be possible to link directly to the
HTML.
2020-05-11 20:51:29 +02:00
Benjamin Berg
a464f602ca nbis: Apply patch to fix scan-build warnings
Apply the newly added patch to the checkout.
2020-05-07 14:22:02 +00:00
Benjamin Berg
ad17011e68 nbis: Add patch to fix warnings reported by scan-build
This patch basically only adds annotations. None of the errors can be
hit in practice.
2020-05-07 14:22:02 +00:00
Benjamin Berg
744a71ce08 vfs301: Assert hex string has 2 or more characters
Otherwise static analysis thinks we may end up allocating a 0 byte
output buffer.
2020-05-07 14:22:02 +00:00
Benjamin Berg
422fc5facf tests: Add unused annotation
The variables exist for memory management but are unused otherwise. Tag
them as such.
2020-05-07 14:22:02 +00:00
Benjamin Berg
6d542edf8a test: Remove unused initialisers
Make the static analysis happy.
2020-05-07 14:22:02 +00:00
Benjamin Berg
8d4d56b1f1 tests: Annotate a few variables as unused
These solely exist for memory management, but the static analysis
complains.
2020-05-07 14:22:02 +00:00
Benjamin Berg
6e30a1ee45 print: Fix "possible leak" warning by moving initialization
For some reason static checkers report that the auto-free is not run if
the goto exists the loop. It seems to me like that should work fine, but
we can simply make the analysers happy by moving it.
2020-05-07 14:22:02 +00:00
Benjamin Berg
87c3b9c5ba upekts: Fix possible NULL pointer access
Reported by scan-build.
2020-05-07 14:22:02 +00:00
Benjamin Berg
0a08a6a7c0 ci: Run clang scan-build test as part of CI 2020-05-07 14:22:02 +00:00
Benjamin Berg
9db89e00d0 elan: Downgrade g_message to debug severity
See: #211
2020-05-07 13:55:35 +00:00
Benjamin Berg
3ad65b9589 vfs5011: Prevent too small images
We need more than 1 line for assembling, but in general, we should
have a reasonable amount of lines. So use the width in the hope we'll
get an image that is about square at least.

Closes: #135
2020-05-07 13:55:35 +00:00
Benjamin Berg
48aa6d0252 upekts: Fix regression during initialisation
The driver has two helper functions to format a command. In one case,
the function was accidentally changed during the port to the new driver
APIs.

See https://bugzilla.redhat.com/show_bug.cgi?id=1832229
2020-05-07 09:55:13 +02:00
Michal Prívozník
eefc954f91 context: Fix order of PID/VID in a debug message
When no driver is found for an USB device a debug message is
printed. However, it has PID and VID in wrong order - usually it
is Vendor ID which goes first. This is how 'lsusb' prints it.
Matching the order helps debugging.

Signed-off-by: Michal Privoznik <michal@privoznik.com>
2020-04-27 16:16:43 +02:00
Michal Prívozník
5bcf9ac008 print: Include "fpi-compact.h"
In the fpi_print_fill_from_user_id() GDate is defined using
g_autoptr(). However, this requires new enough GLib. For older
versions there's a definition provided locally in fpi-compact.h.
Include the file to fix build with older version of GLib.

Signed-off-by: Michal Privoznik <mprivozn@redhat.com>
2020-04-27 16:16:39 +02:00
Benjamin Berg
d2402309ee examples: Cancel verify operation on Ctrl+C
This makes it easier to do basic testing of cancellation paths in the
drivers.
2020-04-24 18:40:48 +00:00
Benjamin Berg
a651b65401 example: Cancel enroll operation on Ctrl+C
This makes it easier to do basic testing of cancellation paths in the
drivers.
2020-04-24 18:40:48 +00:00
Marco Trevisan (Treviño)
bc3f622b2a context: Factorize duplicated code 2020-04-24 20:21:01 +02:00
Marco Trevisan (Treviño)
5de49b33e6 image-device: Terminate the current action with error on print failure
If we fail when setting the scanned image to a print, we'll have a fatal
error, in such case we can terminate the current action and deactivate the
device.
2020-04-24 20:09:56 +02:00
Marco Trevisan (Treviño)
81e198c034 image: Return an error if we got an empty or NULL minutiae array
In some cases nbim's get_minutiae returns no minutiae without providing an
error code, and if this happens we would crash in the task callback function
as we would try to deference the data->minutiae pointer.

Related to: #251
2020-04-24 20:09:56 +02:00
Marco Trevisan (Treviño)
c0895a858d etes603: Return TOO_SHORT retry error for small images
If the image height is less than the sensor horizontal resolution, then
return a retry error rather than trying to submit the image for further
processing.

Related to: #251
2020-04-24 20:03:51 +02:00
Benjamin Berg
5d5995f201 image: Check for task success rather than just cancellation
The minutiae detection might fail and we must not copy any data at that
point. So check g_task_had_error to ensure that we only do so when the
task was successful.

Fixes: #251
2020-04-24 20:03:37 +02:00
Benjamin Berg
f71045b743 synaptics: Use the FpPrint ID generation functionality
As the functionality is now part of the internal FpPrint API, it makes
sene to use it.
2020-04-20 16:43:52 +02:00
Benjamin Berg
0274d0783b print: Add helpers to generate a unique print ID containing metadata
It makes sense to include this functionality in the core library as more
than one driver will be using it soon.
2020-04-20 16:43:52 +02:00
Bastien Nocera
5c5a4f6907 upekts: Fix memory leak
Don't allocate a new finger print structure,
the fpi_device_get_enroll_data() just below will overwrite it.
2020-04-15 15:55:39 +02:00
Bastien Nocera
5b6f5c9aad synaptics: Don't pass always-NULL value
No need to pass "error" to this report function, it will always be NULL.
2020-04-15 15:55:39 +02:00
Marco Trevisan (Treviño)
41e05b1133 test-fpi-device: Don't compare error pointers that have been cleared
During verify/identify complete we replace the error pointer that the driver
returned with another error we created, after clearing that one.

However, when we initialize a new error the compiler may reuse the same
allocation of the cleared one, and this might lead to a test failure.

So, don't be so fragile and ignore the pointer check
2020-04-15 14:19:53 +02:00